IIT Home    BCPS Dept.    The Sensor Research Group    News    Resume    Contact


 

 

 

PUBLICATIONS


 

  • Stetter, J. R. "Electronic Noses: Analytical Tool or Scientific Toy?" In: Artificial Chemical Sensing: Proceedings of the Eighth International Symposium on Olfaction and the Electronic Nose (ISOEN 2001), J.R. Stetter and W.R. Penrose, Eds., March 26-28, 2001, Washington, DC, The Electrochemical Society, pages 1-8. (In press.)
  • Book: Artificial Chemical Sensing: Proceedings of the Eighth International Symposium on Olfaction and the Electronic Nose (ISOEN 2001), J.R. Stetter and W.R. Penrose, Eds., March 26-28, 2001, Washington, DC, The Electrochemical Society, 229 pages. (In press.)
  • Stetter, J. R., W. R. Penrose, S. Kubba, F. Kocka,C. M. McEntegart, R.R. Roberts, and M. A. Iademarco,"Enhancement of the Sensitivity of the electronic nose for bacterial applications." In: Artificial Chemical Sensing: Proceedings of the Eighth International Symposium on Olfaction and the Electronic Nose (ISOEN 2001), J.R. Stetter and W.R. Penrose, Eds., March 26-28, 2001, Washington, DC, The Electrochemical Society, pages 134-138. (In press.)
  • McEntegart, C.M., W.R. Penrose, S. Strathmann, and J.R. Stetter, "Detection and discrimination of coliform bacteria with gas sensor arrays," Sensors and Actuators B, 70, 170-176, 2000.
  • J.R. Stetter, S. Strathmann, C. McEntegart, M. Decastro, and W.R. Penrose, "New Sensor arrays and sampling systems for a modular electronic nose," Sensors and Actuators B, 69, 410-419, 2000.
  • N. Barsan, J.R. Stetter, M. Findlay, W. Göpel, "High Performance Gas Sensing of CO:Comparative Tests for semiconducting (SnO22-based) and for Amperometric Gas Sensors," Anal. Chem., 1999, 71, 2512-2517.
  • P. J. Hesketh, S. Zivanovic, S. Pak, B. Ilic, L. St.Clair, B. Shih, K.Y. Chung, J. C. Cunneen, S. Cariffini, J. G. Boyd, J. R. Stetter, And S. M. Lunte And G. S. Wilson, "Biosensors and Microfluidic Systems," in Tribology in MEMS, Ed. B. Bhushan, Kluwer Science Publications, (1998).
  • C-D. Feng, S-L Sun, H. Wang, C. U. Segre, and J. R. Stetter, "Humidity Sensing Properties of Nafion and Sol-gel-derived SiO2-Nafion Composite Thin Films," Sensors and Actuators, 1997, B 40, 217-222.
  • H. Wang, C-D. Feng, S-L Sun, C. U. Segre, and J. R. Stetter, " Comparison of Conductimetric Humidity Sensing Polymers," Sensors and Actuators, 1997, B 40, 211-216.
  • C.D. Feng, Yu-Dong Ming, P.J. Hesketh, S.M. Gendel and J. R. Stetter, "Confirmantion of immobilizing IgG on different surfaces with AFM and impedance investigations of a Pt electrode during immobilization" Sensors and Actuators B 35 (1996) 431-434.
  • Ollison, W.M., W.M. Penrose, and J.R. Stetter, "Sensitive Measurement of Ozone Using Amperometric Gas Sensor", Analytica Chemica Acta, 313 [1995] 209-219.
  • DeSilva, Mutha S., Steven M. Gendel, Peter J. Hesketh, G.J. Maclay, and J.R. Stetter, "Impedance Based Sensing of the Specific Binding Reaction between Staphylococcus Enterotoxin B and its Antibody on an Ultra-Thin Plantinum Film", BioSensors and BioElectrics, 10 [1995] 675-682.
  • Stetter, J.R., "Amperometric Electrochemical Gas Sensors: Description and Applications," NIST Workshop on Gas Sensors: Strategies for Future Technologies, Sept. 8-9, [1993] 61-64. [NIST Special Pub. #865]. Attari, A., W.J. Buttner, S.S. Chao, K.M. Schroeder, and J. R. Stetter, "A Field Portable Alkyl Arsine Detector", A.I.Ch.E. Journal, [1993].
  • M.W. Findlay, W.R. Penrose, J.R. Stetter, "Quality Classification of Grain Using a Sensor Array and Pattern Recognition", Analytical Chimica Acta, 284 [1993] 1-11.
  • Chang, S.C., Stetter, J.R., Cha, C.S., "Amperometric Gas Sensors", Talanta, 40, No. 4, pp 461-467, (1993).
  • Moyer, E.S., M.W. Findlay, G.J. Maclay, and J.R. Stetter, "Preliminary Evaluation of an Active End-of-Service-Life Indicator for Organic Vapor Cartridge Respirators", American Industrial Hygiene Association Journal, 54(8):417-425 (1993)
  • Stetter, JR, WR Penrose, GJ Maclay, WJ Buttner, MW Findlay, Z. Cao, LJ Luskus, and JD Mulik, "The Electrochemical Sensor: One Solution for Pullution," in ACS Symposium Series:508. Pollution Prevention in Industrial Processes, J.J. Breen and M.J. Dellarco, eds., 101-117, 1992. [ISBN 0-8412-2478-1]
  • Stetter, J.R., "Chemical Sensor Arrays: Practical Insights and Examples, in "Sensors and Sensory Systems for an Electronic Nose," J.Gardner and P.N. Bartlett, eds., Kluwer Academic Publishers [1992] 273-301.
  • Ballantine, D.S.,Jr., D. Callahan, G.J. Maclay, and J.R. Stetter, "An Optical Waveguide Acid Vapor Sensor", Talanta, 39(12), 1657-1667, (1992).
  • Cao, Z., W.J. Buttner, and J.R. Stetter, "The Properties and Applications of Amperometric Gas Sensors", Electroanalysis, 4, 253-266 (1992).
  • Book Contribution: "Human Exposure Assessment for Airborne Pollutants: Advances and Opportunities", [written by the National Research Council Committee on Advances is Assessing Human Exposure to Airborne Pollutants, Paul Lioy, Committee Chairman, J. Stetter committee member], Pub. by Nat. Academy of Sciences Press, Wash., DC 20418, (1991).ISBN 0-309-04284-4.
  • Stetter, J.R., C-X. Shi, and G.J. Maclay, "Modulated Photoionization Detection of Hydrazine Compounds in Mixtures without Prior Separation", Analytical Chemistry, 63(17), 1755-1759, (1991).
  • Cao, Z. and J.R. Stetter, "Amperometric Gas Sensors," in Chemical and Biological Sensors, M. Madou and J. Joseph, eds., NIST Publication GCR 91-593-1 [Oct. 1991].
  • Maclay, G.J., C. Yue, M.W. Findlay, and J.R. Stetter, "An Active End Service Life for Respirator Cartridges," Appl. Occupational and Env. Hygiene, 6(8), 677-682, (1991).
  • Cao, Z. and J. R. Stetter, "A Selective Solid State Gas Sensor for Halogenated Hydrocarbons," Sensors and Actuators, B,5, 109-113, 1991.
  • Buttner, William J., G.J. Maclay,and J.R. Stetter, "An Integrated Amperometric Microsensor," Sensors and Actuators, B1, 303-307, (1990).
  • Stetter, J.R., S. Chang, "Electrochemical NO2 Gas Sensors: Model and Mechanism for the Electroreduction of NO2," Eletroanalysis, 2, (1990).
  • Buttner, W.J., J.R. Stetter, and G.J. Maclay, "Microfabricated Amperometric Gas Sensors with and Integrated Design," Sensors and Materials, 2, 99-106 (1990).
  • Stetter, J.R,, and Z. Cao, "Gas Sensor and Permeation Apparatus for the Determination of Chlorinated Hydrocarbons in Water," Analytical Chemistry, 62, 182, (1990).
  • Stetter, J.R., M.W. Findlay, G.J. Maclay, J. Zhang, S. Vaihinger, and W. Göpel, "Sensor Array and Catalytic Filament for Chem. Anal. of Vapors and Mixtures," Sensors and Actuators, B1, 43-47, (1990).
  • Stetter, J.R., G.J. Maclay, and S.V. Christesen, "Time-dependent Sensor Signals for Selective Detection," Sensor and Actuators, 20(3), 277-287, (1989).
  • Stetter, J.R., G.J. Maclay, and W.J. Buttner, "Microfabricated Amperometric Gas Sensor," IEEE Trans. On Electron Devices 35(6), 793 (1988).
  • Otagawa, T., S. Zaromb, and J. R. Stetter, "Cryogenic Sampling for Aniline Vapors with subsequent LC/EC Analysis," J. Chromatogr., 408, 81-92 (1987).
  • T. Otagawa, J.R. Stetter, and S. Zaromb, "Portable Liquid Chomatograph for Analysis of Primary Aromatic Amines in Coal-derived Materials," J. Chromatogr. 360, 252-259 (1986).
  • Stetter, J.R., P.C. Jurs, and S.L.Rose, "Detection of Hazardous Gases and Vapors: Pattern Recognition Analysis of Data from an Electrochemical Sensor Arrays," Anal. Chem. 58, 860-866 (1986).
  • Stetter, J.R., and T. Otagawa, "A Chemical Concentration - Modulation Sensor for the Selective Detection of Airborne Chemicals," Sensors and Actuators, 11 (3) 251-264 (1987).
  • Stetter., J.R., "Electrochemical Sensors, Sensor Arrays, and Computer Algorithms," in Fundamentals and Applications of Chemical Sensors," D. Schuetzle, R. Hammerle, and J. Butler, eds., ACS Symposium Series, No. 309, 299-308 (1986).
  • Otagawa, T., S. Zaromb, and J.R. Stetter, "Selective Detection of Primary Aromatic Amines in Complex Mixtures by Liquid Chromatography with Electrochemical Detection Using a Short Reversed-Phase Column," in Proc. of the 24th Hanford Life Sciences Symp: Health and Enviornmental Research on Complex Organic Mixtures, R.H. Gray, ed., Battelle Pacific Northwest Laboratories; Richland, Wa., October 20-24, 1985, pp 27-47 (1987).
  • Stetter, J.R., W.R. Penrose, S. Zaromb, J.O. Stull, et al., "A Portable Toxic Vapor Detector and Analyzer Using an Electrochem. Sensor Array," in Analysis Inst., K.S.Herbst, ed.,V 21, 163-170, pub. by ISA, RTP, NC 27709, (1985).
  • Zimmerman, R.E., J.R. Stetter, and L.L. Altpeter, "Process Monitoring for Trace Sulfur and Chlorine Compounds in Landfill Generated Methane," Anal. Instr., V. 21, 89-102, K.S. Herbst, ed., pub by ISA, RTP, NC 27709, U.S.A. (1985).
  • Otagawa, T., S. Zaromb, and J.R. Stetter, "Electrochemical Oxidation of Methane in Nonaqueous Electrolytes at Room Temperature: Application to Gas Sensors," Journal of Electrochemical Society 132(12):2951-2957 (1985)
  • Otagawa, T., S. Zaromb, and J.R. Stetter, "A Room-Temperature Electro- chemical Sensor and Instrument for Monitoring Methane," Journal of Sensors and Actuators, 8, 65-88 (1985).
  • Stetter, J.R., V.C. Stamoudis, and A.D. Jorgensen, "Interactions of Aqueous Metal Ions with Organic Compounds found in coal Gasification: Process Condensates," Environmental Science and Technology 19(10):924-928 (1985).
  • Jorgensen, A.D., J.R. Stetter, and V.C. Stamoudis, "Interactions of Aqueous Metal Ions with Organic Compounds found in Coal Gasification: Model systems," Environmental Science and Technology 19(10):919-923 (1985).
  • Zaromb, S., and J.R. Stetter, "Theoretical Basis for Identification and Measurement of Air Contaminants Using an Array of Sensors Having Partly Overlapping Selectivities," Sensors and Actuators 6:225-243 (1985).
  • Stetter, J.R., S. Zaromb, and M.W. Findlay, Jr., "Monitoring of Electrochemically Inactive Compounds by Amperometric Gas Sensors," Sensors and Actuators 6:269 (1985).
  • Osborne, J.F., S. Santhanam, C.I. Davidson, R.D. Flotard, and J.R. Stetter, "Characterization of Airborne Trace Metal and Trace Organic Species from Coal Gasification," Environmental Monitoring and Assessment, 4, 317-333, (1984).
  • Stetter, J.R., "Instrumentation to Monitor Chemical Exposure in the Synfuel Industry," Annals American Conf. of Governmental and Industrial Hygienists, 11, 225-269, (1984).
  • Stetter, J.R., R.J. Young, and G. McCarty, "Evaluation of a Novel Impinger," Annals of the American Conf. of Governmental and Industrial Hygienists, 8, 101-105, (1984).
  • Stetter, J.R., and S. Zaromb, "A Dynamic Coulometric Technique for Gas Analysis," J. Electroanal. and Interfacial Electrochem., 148:271-277 (1983).
  • Zaromb, S., J.R. Stetter, and D. O'Gorman, "Determination of Carbon Monoxide in Air by Dynamic Coulometry," J. Electroanal. and Interfacial Electrochem. 148:279-287 (1983).
  • Zaromb, S., J.R. Stetter, and G.J. Attard, "The Potential-Dependence of the Electro-oxidation of Nitric Oxide on Gold in Acid Solution." Journal Electroanal. and Interfacial Electrochem. 148:289-291 (1983).
  • Jorgensen, A.D., and J.R. Stetter, "The Effect of Trace Metal Ions on the Analysis of Organic Mixtures with application to Synthetic Fuel Samples," Anal Chem., 54:381 (1982).
  • Davidson, C.I., S. Santhanan, J.R. Stetter, R.D. Flotard, and E. Gebert, "Characterization of Airborne Particles at a High-Btu Coal-Gasification Pilot Plant," Environmental Monitoring and Assessment, 1:313-335 (1982).
  • Hubble, B.R., J.R. Stetter, E. Gebert, J.B.L. Harkness, R.D. Flotard, "Experimental Measurements of Emissions from Residential Wood-Burning Stoves," in Residential Solid fuels, Environmental Impacts and Solutions, J.A. Cooper and D. Malek, eds., pub. by Oregon Graduate Center, Beaverton, OR., 79-135, (1982).
  • Stetter, J.R., Conf. Report, ISA/81 "Spring Conference and Exhibit," J. Phys. E., Sci. Instr., 14, 1025, (1981).
  • Stetter, J.R., "Environmental Analyses: Application of Computer-Controlled Chromatography," in Analysis Instrumentation, V. 19, 89-94, T. Lastrapes and J. Bogart, eds., ISA Proc. of 27th Anal. Instr. Symposium, St. Louis, MO., published by Instrument Society of America, Research Triangle Park, N.C., (Mar. 1981).
  • Flotard, R.D., J.R. Stetter, and V.C. Stamoudis, "Workplace Air Sampling at Coal-Conversion Facilities," in Coal Conversion and the Environment: Chemical, Biological and Ecological Considerations, Proc. 20th Hanford Life Sciences Symp., Richland, WA (Oct. 1980), Mahlum, D.D., R.H. Gray, and W.D. Felix, eds., U.S.Doe Symp. Series 54, Conf.-80-1039, NTIS, 159-172, (1981).
  • Stamoudis, V.C., S. Bourne, D.A. Haugen, M.J. Peak, C.A. Reilly, J.R. Stetter, and K. Wilzbach, "Chemical and Biological Characterization of High-Btu Coal-Gasification (The HYGAS Process I), , Proc. 20th Hanford Life Sciences Symp., Richland, WA (Oct. 1980), Mahlum, D.D., R.H. Gray, and W.D. Felix, eds., U.S.Doe Symp. Series 54, Conf.-80-1039, NTIS, pages 67-96, (1981).
  • Stetter, J.R., and D.R. Rutt, "Instrumental Carbon Monoxide Dosimetry," Am. Ind. Hygiene J., 41, 704, (1980).
  • Stetter, J.R., and K.F. Blurton, "Catalytic Oxidation of CO and H2 Mixtures in Air," Ind and Eng. Chem., Prod. Res. and Dev., 19(2), 214, (1980).
  • Stetter, J.R., K.A. Tellefsen, R.A. Saunders, and J.J. DeCorpo, "Electrochemical Determination of Hydrazine, Methyl and 1, 1-Dimethlhydrazine in Air," Talanta, 26, 709, (1979).
  • Stetter, J.R., K.F. Blurton, A.M. Valentine, and K.A. Tellefson, "The Electrochemical Oxidation of Hydrazine and Methylhydrazine on Gold: Application to Gas Monitoring," J.Electrochem.Soc., 125, 1804-1807, (1978).
  • Stetter, J.R., "A Surface Chemical View of Gas Detection," J. Colloid & Interface Sci.,65(3), 432-443, (1978).
  • Blurton, K.F., and J.R. Stetter, "A Sensitive Electrochemical Detector for Gas Chromatography," J. of Chromatography, 155, 35-45, (1978).
  • Stetter, J.R., J.M. Sedlak, and K.F. Blurton, "Electrochemical Gas Chromatographic Detection of Hydrogen Sulfide at PPM and PPB Levels," J. of Chromatographic Science, 15, 125-128, (1977).
  • Blurton, K.F., and J.R. Stetter, "The Gas Phase and Electrochemical Oxidation of Carbon Monoxide on Platinum, Palladium, and Ruthenium Catalysts: A Comparative Study," J. of Catalysis, 46, 230-233, (1977).
  • Stetter, J.R., and K.F. Blurton, "Selective Oxidation of Hydrogen in Carbon Monoxide/Air Streams: Applications to Environmental Monitoring," Industrial and Engineering Chemistry: Product Research and Dev., 16, 22-25, (1977).
  • Stetter, J.R., and K.F. Blurton, "Portable High Temperature Catalytic Reactor: Application to Air Pollution Monitoring Instrumentation," Review of Scientific Instruments, 47, 691, (1976).
  • Stetter, J.R., D.R. Rutt, and K.F. Blurton, "Portable Gas Chromatograph and Electrochemical Detector for Carbon Monoxide," Anal. Chem., 48, 924, (1976).
  • Cadenhead, D.A., and J.R. Stetter, "Specific Gravities of Lunar Materials Using Helium Pycnometry," Proc. 6th Lunar Science Conf. (Suppl. 6, Geochimica et Cosmochimica Acta), 3199-3206, (1975).
  • Cadenhead, D.A., and J.R. Stetter, "The Interaction of Water Vapor with Lunar Soil, a Compacted Soil, and a Cinder-Like Rock Fragment," Proc. of the 5th Lunar Science conference (Supplement 5, Geochimica et Cosmochimica Acta), Pergamon Press, 3, 2301-2316, (1974).
  • Cadenhead, D.A., J.R. Stetter, and W.G. Buergel, "Pore Structure in Lunar Samples," J. Colloid Interface Science, 47, 322-336, (1974).
  • Cadenhead, D.A., B.R. Jones, J.R. Stetter, and W.G. Buergel, "Solar Wind and Terrestrial Atmosphere Effects on Lunar Sample Surface Composition," Proc. of the 4th Lunar science Conference (Supplement 4, Geochimica et Cosmochimica Acta), Pergamon Press, 3, 2391-2401, (1973).